8800p Al2O3 Trace Teledyne Analytical Instruments Gas Moisture Analyzer
  • 8800p Al2O3 Trace Teledyne Analytical Instruments Gas Moisture Analyzer
  • 8800p Al2O3 Trace Teledyne Analytical Instruments Gas Moisture Analyzer

8800p Al2O3 Trace Teledyne Analytical Instruments Gas Moisture Analyzer

Place of Origin Teledyne
Brand Name Teledyne
Certification ROHS
Model Number 8800P
Product Details
Origin:
USA
Warranty:
1 Year
Manufacturer:
Teledyne
Products Name:
Teledyne Trace Moisture Analyzer
Model:
8800P
Sensor Type:
High Capacitance Al2O3 (HTF)
​Range:
Standard: 25 Psi (2 Bar) Max: 100 Psi (6.9 Bar)
Readouts:
​Dewpoint In °F And °C, Ppmv, HH2o/m3, Lbs H2o/mmscf
​Accuracy:
​± 5.5°F (± 3°C)
​Repeatability:
​± 0.9°F (± 0.5°C)
Capacitance:
15 NF To 200 NF
Highlight: 

Al2O3 Teledyne Analytical Instruments

,

8800p Teledyne Analytical Instruments

,

Teledyne gas moisture analyzer

Payment & Shipping Terms
Minimum Order Quantity
1PC
Price
negotiable
Packaging Details
carton
Delivery Time
on request
Payment Terms
T/T
Supply Ability
1~1000pcs
Product Description
8800p Al2O3 Trace Teledyne Analytical Instruments Gas Moisture Analyzer
Product Description
Teledyne Trace Moisture Analyzer 8800P

Part Number: 8800P

Product Name: Trace Moisture Analyzer

Origin: USA

Manufacturer: Teledyne

Specification

The 8800 Series Single Point Trace Moisture Analyzers are provided in four compact, reliable designs with the ability to detect moisture from -148°F (-100°C) to ambient dew point levels of +68°F (+20°C) on either a continuous or spot checking basis.

  • 8800A - Flush Mount DIN enclosure with connections made via a pluggable screw terminal block
  • 8800B - Wall Mount N4X (IP65) enclosure with connections made with 3 bottom watertight fittings
  • 8800P - Portable battery operated design in the Standard, I/O and I/S versions (I/S is suitable for hazardous areas)
  • 8800T - Low-cost, loop powered 4-20 mA transmitter design with built-in LCD display
Features
  • Readout available in (5) engineering units; °C, °F, ppm, lbs. H2O/mm scf & g H2O/m3
  • Scalable signal outputs (0-20 mADC & 4-20 mADC)
  • Built-in LCD with backlight, 3.5 digits and custom legends for units / mode
  • Din box enclosure: (cut-out dimensions of 137 mm W x 67 mm H)
  • (4) front panel membrane tactile push button controls, all settings stored in EEPROM
  • (2) programmable alarm relays w/programmable variable hysteresis rated 10A @ 240V
  • Power requirements of 100-240 VAC, 50 or 60 Hz
  • Operating temperature of electronics: -10 to 50° C
  • Class I & II, Division 1, Groups A, B, C, D, E, F & G (when used with optional safety barriers)
  • High capacitance aluminum oxide (Al2O3) sensor using Hyper Thin Film (HTF)™ Technology
  • (2) meters of sensor interconnection cable included
  • Power cord
  • Instruction manual (one copy per analyzer ordered)
Oxygen Sensor Specifications
Model Part Number Description Application
A-2C C6689-A2C Used for trace O2 measurements in CO2 containing backgrounds (0.1-100% CO2). CO2 must be present. Use where acid gases are present (CO2, HCl, HCN, etc). CO2 must be present.
A-2CXL B74033-A2CXL Specially qualified A2C sensor to operate in XL model analyzers. Low range limit is 0-1 ppm. Use where acid gases are present (CO2, HCl, HCN, etc). CO2 must be present.
A-5 C6689-A5 Intermittent or continuous monitoring of percent O2 in gas mixtures containing 0-100% CO2. 90% response is time is 45 seconds. Has more tolerance to exposure to air than A-3. No restrictions on CO2 concentration.
B-1 C6689-B1 General purpose percent oxygen analysis where fast response is desired (90% in less than 7 seconds). Use B-3 or C-3 where longer life is required and response time is relatively unimportant. May be used to spot check flue gas.
B-2C C6689-B2C General purpose trace O2 analysis for use in inert gas and hydrocarbon streams. Low range limit is 0-10 ppm. May be used in CO2 free gas streams containing highly mobile gases such as H2, He and ethylene.
INSTA TRACE B71875 Special patented construction provides rapid recovery, during initial cell installation, to low PPM levels by reducing the recovery period from several hours to just minutes. Low range limit is 0-10 ppm. Used for trace O2 analysis in inert gas and hydrocarbon streams.
Common Models
3000MA
3010MA
3110(311D)
311TC
3000TA
311
311XL
311TCXL
311PC
3190
320P
3010PAC
4020
8800A
INSTATRANS 3001
INSTATRANS-XD
3290
A-2C
L-2C
B-2CXL
A-5
B-2C
B-37937
UFO-130-2
C73870
C65098A
D67472REV8
GB300
INSTA TRACE (B71875)
R-22A
Our Advantage
  • Best possible prices and delivery time
  • Long time experience in the field
  • Well trained staff
  • Own warehouse facilities
  • Best relationships with branch office of manufacture
  • Flexible and individual service for you
  • Cheap and safe forwarder for shipments (air)
Frequently Asked Questions
Q: Does your goods are new and original?

A: Yes, they are new and original.

Q: How long warranty?

A: One-year warranty.

Q: Does any certificates can be provided?

A: Yes, it depends on what product you request, please check details with our sales.

Q: Varied payment methods.

A: We adopt T/T, alipay and paypal and Currency in EURO,USD,RMB

Q: SHIPPING:

A: We can shipping all over the world.via DHL,UPS,Fedex,TNT and IPS,PDE,BRE,KARAPOST etc.

Our Product Range:

Transmitter, Safety barries, Flow meters, Probe, Sensor, Transducer. Valves,Analysis meter, Positioner, Acuator, etc.

8800p Al2O3 Trace Teledyne Analytical Instruments Gas Moisture Analyzer 0 8800p Al2O3 Trace Teledyne Analytical Instruments Gas Moisture Analyzer 1

Contact Us at Any Time

86-755-26850710
Flat 10, 6/F, Block A, Hi-Tech Ind. Ctr. 5-21 Pak Tin Par St, Tsuen Wan, HK
Send your inquiry directly to us