GREAT SYSTEM INDUSTRY CO. LTD
e-posta: jim@greatsystem.cn Tel:: 852--3568 3659
Evde > Ürünler > mtl güvenlik bariyeri >
9V DC MTL5511 MTL Safety Barrier Switch Proximity Detector Interface
  • 9V DC MTL5511 MTL Safety Barrier Switch Proximity Detector Interface
  • 9V DC MTL5511 MTL Safety Barrier Switch Proximity Detector Interface
  • 9V DC MTL5511 MTL Safety Barrier Switch Proximity Detector Interface

9V DC MTL5511 MTL Safety Barrier Switch Proximity Detector Interface

Place of Origin UK
Marka adı MTL
Sertifika ROHS
Model Number MTL5511
Ürün Ayrıntıları
Color:
White and blue
material:
plastic and metal
Shipping Weight:
1.0Kg
Dimensions ( D x W x H ):
1.58 cm x 10.98 cm x 12.36 cm
Number of channels:
One
Voltage applied to sensor:
7 to 9V dc from 1kO ±10%
Product No:
MTL5511
Estimated Lead Time:
Usually ships in 1-7 working days.
Vurgulamak: 

MTL5511 MTL Safety Barrier

,

9V MTL Safety Barrier

,

MTL safety barrier instrument

Ödeme ve Nakliye Şartları
Minimum Order Quantity
1
Fiyat
negotiable
Packaging Details
carton
Delivery Time
on request
Payment Terms
T/T
Supply Ability
100+pc+on stock
Ürün Tanımı
MTL5511 MTL Safety Barrier Switch Proximity Detector Interface
The MTLx511 enables a safe-area load to be controlled by a switch or proximity detector located in a hazardous-area. Inputs conform to BS EN60947-5-6:2001 standards for proximity detectors (NAMUR).
Key Features
  • Hazardous-area inputs conforming to BS EN60947-5-6:2001 standards
  • Voltage applied to sensor: 7 to 9V dc from 1kΩ ±10%
  • User-selectable line fault detection with LED indication
  • Single pole relay with changeover contacts for safe-area output
Technical Specifications
Parameter Value
Input/Output Characteristics Normal phase
Output State Closed if input > 2.1mA (< 2kΩ), Open if input < 1.2mA (> 10kΩ)
Hysteresis 200µA (650Ω) nominal
Line Fault Detection (LFD) Open-circuit alarm: on if Iin < 50µA, off if Iin > 250µA
Short-circuit alarm: on if Rin < 100Ω, off if Rin > 360Ω
Resistor Requirements 500Ω to 1kΩ in series with switch
20kΩ to 25kΩ in parallel with switch
Important Notes
  • Resistors must be fitted when using the LFD facility with a contact input
  • Reactive loads must be adequately suppressed
About Great System Inc. (GSI)

Since 1998, GSI has been a quality leader in Process Control Instrumentation and Electrical Instrument Solutions, headquartered in Hong Kong, China.

Herhangi bir zamanda bizimle iletişime geçin

86-755-26850710
Flat 10, 6/F, Block A, Hi-Tech Ind. Ctr. 5-21 Pak Tin Par St, Tsuen Wan, HK
Sorgularınızı doğrudan bize gönderin.