GREAT SYSTEM INDUSTRY CO. LTD
อีเมล: jim@greatsystem.cn โทร:: 852--3568 3659
บ้าน > ผลิตภัณฑ์ > mtl ป้องกันความปลอดภัย >
9V DC MTL5511 MTL Safety Barrier Switch Proximity Detector Interface
  • 9V DC MTL5511 MTL Safety Barrier Switch Proximity Detector Interface
  • 9V DC MTL5511 MTL Safety Barrier Switch Proximity Detector Interface
  • 9V DC MTL5511 MTL Safety Barrier Switch Proximity Detector Interface

9V DC MTL5511 MTL Safety Barrier Switch Proximity Detector Interface

Place of Origin UK
ชื่อแบรนด์ MTL
ได้รับการรับรอง ROHS
Model Number MTL5511
รายละเอียดสินค้า
Color:
White and blue
material:
plastic and metal
Shipping Weight:
1.0Kg
Dimensions ( D x W x H ):
1.58 cm x 10.98 cm x 12.36 cm
Number of channels:
One
Voltage applied to sensor:
7 to 9V dc from 1kO ±10%
Product No:
MTL5511
Estimated Lead Time:
Usually ships in 1-7 working days.
เน้น: 

MTL5511 MTL Safety Barrier

,

9V MTL Safety Barrier

,

MTL safety barrier instrument

เงื่อนไขการชําระเงินและการจัดส่ง
Minimum Order Quantity
1
ราคา
negotiable
Packaging Details
carton
Delivery Time
on request
Payment Terms
T/T
Supply Ability
100+pc+on stock
คําอธิบายสินค้า
MTL5511 MTL Safety Barrier Switch Proximity Detector Interface
The MTLx511 enables a safe-area load to be controlled by a switch or proximity detector located in a hazardous-area. Inputs conform to BS EN60947-5-6:2001 standards for proximity detectors (NAMUR).
Key Features
  • Hazardous-area inputs conforming to BS EN60947-5-6:2001 standards
  • Voltage applied to sensor: 7 to 9V dc from 1kΩ ±10%
  • User-selectable line fault detection with LED indication
  • Single pole relay with changeover contacts for safe-area output
Technical Specifications
Parameter Value
Input/Output Characteristics Normal phase
Output State Closed if input > 2.1mA (< 2kΩ), Open if input < 1.2mA (> 10kΩ)
Hysteresis 200µA (650Ω) nominal
Line Fault Detection (LFD) Open-circuit alarm: on if Iin < 50µA, off if Iin > 250µA
Short-circuit alarm: on if Rin < 100Ω, off if Rin > 360Ω
Resistor Requirements 500Ω to 1kΩ in series with switch
20kΩ to 25kΩ in parallel with switch
Important Notes
  • Resistors must be fitted when using the LFD facility with a contact input
  • Reactive loads must be adequately suppressed
About Great System Inc. (GSI)

Since 1998, GSI has been a quality leader in Process Control Instrumentation and Electrical Instrument Solutions, headquartered in Hong Kong, China.