3500/62 163179-03 BENTLY NEVADA 3500/62 Process Variable Monitor PLC Module
The 3500/62 (163179-03) is a mechanical protection system module designed for industrial applications.
Product Description
The 3500/62 Process Variable Monitor is a 6-channel monitor for processing machine critical parameters (pressures, flows, temperatures, levels, etc.) that merit continuous monitoring. The monitor accepts +4 to +20 mA current inputs or any proportional voltage inputs between -10 Vdc and +10 Vdc.
It conditions these signals and compares the conditioned signals to user-programmable alarm setpoints. The user can program the 3500/62 using the 3500 Rack Configuration Software to perform either current or voltage measurements.
The 3500/62 offers I/O modules for 3 signal input scenarios:
- +/-10 Volts DC
- Isolated 4-20mA
- 4-20 mA with Intrinsically Safe zener barriers
The Internal Barrier I/O provides external power input terminals to provide intrinsically safe power to the 4-20mA transducers. The primary purposes of the 3500/62 monitor are to:
- Continuously compare monitored parameters against configured alarm setpoints to drive alarms for machinery protection
- Provide essential machine information for both operations and maintenance personnel
When used in a Triple Modular Redundant (TMR) configuration, you must install Process Variable Monitors adjacent to each other in groups of three. In this configuration, the monitor employs two types of voting to ensure accurate operation and to avoid loss of machinery protection due to single-point failures.
Ordering Considerations
If the 3500/62 Module is added to an existing 3500 Monitoring System, the monitor requires the following (or later) firmware and software versions:
- 3500/20 Module Firmware - 1.07 (Rev G)
- 3500/01 Software - Version 2.20
- 3500/02 Software - Version 2.10
- 3500/03 Software - Version 1.20
If the Internal Barrier I/O is used the system must also meet these requirements:
- 3500/62 Module Firmware- 1.06 (Rev C)
- 3500/01 Software - Version 2.30
You cannot use External Termination Blocks with Internal Termination I/O modules. When ordering I/O Modules with External Terminations, you must order the External Termination Blocks and Cables separately.
Internal Barrier I/O Module Important Information
Fuse: Consult the 3500 Internal Barrier specification sheet (part number 141495-01) if you select the Internal Barrier Option. 250 mA, 250 V fast blow type.
Cables
3500/62 Transducer (XDCR) Signal to External Termination (ET) Block Cable 134544-AAAA-BB
- A: Cable Length
- 0005 5 feet (1.5 metres)
- 0007 7 feet (2.1 metres)
- 0010 10 feet (3 metres)
- 0025 25 feet (7.5 metres)
- 0050 50 feet (15 metres)
- 0100 100 feet (30.5 metres)
- B: Assembly Instructions
- 01 Not assembled
- 02 Assembled
Spare Parts
| Part Number |
Description |
| 163179-03 |
3500/62 monitor |
| 136590-01 |
Firmware IC |
| 04425545 |
Grounding wrist strap (single use) |
| 04400037 |
IC removal tool |
| 136491-01 |
-10 Vdc to +10 Vdc I/O Module with internal terminations |
| 136499-01 |
-10 Vdc to +10 Vdc I/O Module with external terminations |
| 136294-01 |
Isolated +4 to +20 mA I/O Module with internal terminations |
| 136483-01 |
Isolated +4 to +20 mA I/O Module with external terminations |
| 137110-01 |
4 to 20 mA Barrier I/O Module with internal terminations |
| 136973 |
3500/62 User Guide |
| 01700059 |
Replacement fuse for barrier I/O |
Our Advantages
- Best possible prices and delivery time
- Long time experience in the field
- Well trained staff
- Own warehouse facilities
- Best relationships with branch office of manufacture
- Flexible and individual service for you
- Cheap and safe forwarder for shipments (air)
Frequently Asked Questions
Q: Does your goods are new and original?
A: Yes, they are new and original.
Q: How long warranty?
A: One-year warranty.
Q: Does any certificates can be provided?
A: Yes, it depends on what product you request, please check details with our sales.