2025-12-17
Micro Motion® ELITE® Coriolis meters are the leading precision flow and
density measurement solutions. ELITE meters offer the most accurate and
repeatable measurement available for liquids, gases, or slurries.
![]()
Micro Motion Coriolis meters meet a vast range of application needs, ranging from extreme low-flow up to
high-flow, high-capacity lines. Cryogenic, hygienic, high-temperature, and high-pressure— Micro Motion
meters can handle them all. Micro Motion meters are available with a variety of wetted parts to ensure the
best material compatibility.
Coriolis meters. Coriolis meters offer dramatic
benefits over traditional volumetric measurement
technologies. Coriolis meters:
• Deliver accurate and repeatable process data
over a wide range of flow rates and process
conditions.
• Provide direct inline measurement of mass flow
and density, and also measure volume flow and
temperature—all from a single device.
• Have no moving parts, so maintenance costs
are minimal.
• Have no requirements for flow conditioning or
straight pipe runs, so installation is simplified
and less expensive.
• Provide advanced diagnostic tools for both the
meter and the process.
ELITE Coriolis meters. Micro Motion ELITE meters
are the leading meters for precision flow and density
measurement. ELITE meters offer the most
accurate measurement available for virtually any
process fluid, while exhibiting exceptionally low
pressure drop. Every ELITE meter features
standard secondary containment, and is available
with stainless steel or nickel-alloy wetted parts and
a wide variety of process connections to meet your
every need.
Now with in-situ meter verification, ELITE delivers
the best in measurement and ease of use for critical
applications. ELITE meters offer the best
measurement performance for mass, density, and
volume, regardless of process or environmental
conditions. ELITE meters provide measurement
capability for two-phase flow, liquid, and gas
custody transfer, and process conditions from
–400 °F (–240 °C) to 662 °F (350 °C).
![]()
Best precision flow and density measurement
Micro Motion ELITE meters are the leading meters for
precision flow and density measurement. ELITE meters are
ideal for custody transfer and critical process control with
unprecedented mass, volume, and density performance on
liquids, gases, and slurries. ELITE meters have exceptional
rangeability or turndown with a 20:1 flat spec at ±0.05% on
liquid and ±0.35% on gas.
Superior performance in the most challenging applications
The robust design of the ELITE meter eliminates environmental and
process effects wile delivering the most sensitive flow measurement
in the industry. Measurement accuracy is unaffected by two-phase
flow or entrained air, and there are no moving parts to wear out or
break down, which translates into minimal
maintenance costs. Now with in-situ meter
verification, ELITE meters deliver the best in
measurement and ease of use for critical
applications.
Broadest range of application coverage
ELITE meters are available to fit an extremely wide range of line sizes. Every ELITE meter features
standard secondary containment, and is available with stainless steel or nickel alloy wetted parts and a
wide variety of process connections to meet your process needs. The electronics options available with
ELITE meters fit a wide range of control systems and installation needs—including 4–20 mA, HART,
PROFIBUS, Modbus, Foundation fieldbus™, and more.
Mass Volume(1)
(1) Specifications for volumetric flow rate are based on a process-fluid density of 1 g/cm3 (1000 kg/m3). For fluids with density other than
1 g/cm3 (1000 kg/m3), the volumetric flow rate equals the mass flow rate divided by the fluid’s density.
lb/min kg/h gal/min l/h bbl/hr m3/h
Maximum flow rate CMF010 4 108 0.4 108
CMF025 80 2180 10 2180
CMF050 250 6800 30 6800
CMF100 1000 27,200 120 27,200
CMF200 3200 87,100 385 87,100 550 87
CMF300 10,000 272,000 1200 272,000 1700 272
CMF400 20,000 545,000 2400 545,000 3400 545
Mass and volume flow
accuracy(2)(3)
(2) Stated flow accuracy includes the combined effects of repeatability, linearity, and hysteresis. All specifications for liquids are based on
reference conditions of water at 68 to 77 °F (20 to 25 °C) and 15 to 30 psig (1 to 2 bar), unless otherwise noted.
(3) The calibration option for ±0.05% flow accuracy is not available with high-temperature sensor models.
Model 2400S transmitter
or enhanced core
processor
±0.05% of rate(4)(5)
(4) When flow rate is less than zero stability / 0.0005, accuracy = ±[(zero stability / flow rate) × 100]% of rate, and
repeatability = ±[½(zero stability / flow rate) × 100]%.
(5) When ordered with the ±0.10% factory calibration option, accuracy on liquid = ±0.10% when flow rate ≥ zero stability / 0.001. When flow
rate < zero stability / 0.001, accuracy = ±[(zero stability / flow rate) × 100]% of rate and
repeatability = ±[½(zero stability / flow rate) × 100]% of rate.
Transmitter with
MVD technology
±0.10% of rate(6)
(6) When flow rate is less than zero stability / 0.001, accuracy = ±[(zero stability / flow rate) × 100]% of rate and
repeatability = ±[½(zero stability / flow rate) × 100]% of rate.
All other transmitters ±0.10% ±[(zero stability / flow rate) × 100]% of rate
![]()
Contact Us at Any Time