GREAT SYSTEM INDUSTRY CO. LTD
Σπίτι > προϊόντα > Ε&H μέσο >
Bently Nevada 9200-09-01-06-04 8mm Proximity Probe Eddy Current Sensor With 24V DC Power And AISI 304 Stainless Steel Case
  • Bently Nevada 9200-09-01-06-04 8mm Proximity Probe Eddy Current Sensor With 24V DC Power And AISI 304 Stainless Steel Case
  • Bently Nevada 9200-09-01-06-04 8mm Proximity Probe Eddy Current Sensor With 24V DC Power And AISI 304 Stainless Steel Case
  • Bently Nevada 9200-09-01-06-04 8mm Proximity Probe Eddy Current Sensor With 24V DC Power And AISI 304 Stainless Steel Case

Bently Nevada 9200-09-01-06-04 8mm Proximity Probe Eddy Current Sensor With 24V DC Power And AISI 304 Stainless Steel Case

Τόπος καταγωγής ΗΠΑ
Μάρκα Bently
Πιστοποίηση Rohs
Αριθμό μοντέλου 9200-09-01-06-04
Λεπτομέρειες για το προϊόν
Καθαρό Βάρος:
2 κιλά
Τροφοδοτικό:
24V DC
Υλικό συμβουλών ανιχνευτή:
Κεραμική αλουμίνα (Al2O3)
Υλικό θήκης του ανιχνευτή:
AISI 304 από ανοξείδωτο χάλυβα
Γραμμική Εύρος:
1,52 mm (60 mils)
Μήκη καλωδίου ανιχνευτή:
0,5, 1, 2, 5 ή 9 μέτρα
Όροι πληρωμής και αποστολής
Ποσότητα παραγγελίας min
1 ΤΕΜ
Τιμή
negotiable
Συσκευασία λεπτομέρειες
αρχική συσκευασία
Χρόνος παράδοσης
5-8 έργα
Όροι πληρωμής
T/T
Δυνατότητα προσφοράς
50 τμχ/μήνα
Περιγραφή του προϊόντος
Bently Nevada 9200-09-01-06-04 8mm Proximity Probe Eddy Current Sensor 24VDC
Product Overview

Bently Nevada™ Seismoprobe Velocity Transducer Systems are designed to measure absolute (relative to free space) bearing housing, casing, or structural vibration. The two-wire systems consist of a transducer and appropriate cable.

The Seismoprobe family of velocity transducers uses moving-coil technology to provide a voltage output directly proportional to the transducer's vibration velocity. These transducers are less sensitive to impact or impulsive excitation than solid-state velocity transducers and don't require external power, making them convenient for portable measurement applications.

Available Types
  • 9200: Two-wire transducer suitable for continuous monitoring or periodic measurements. When ordered with integral cable, it offers excellent resistance to corrosive environments without additional protection.
  • 74712: High temperature version of the 9200 transducer.

Interconnect cables are available in various lengths with or without stainless steel armor for connecting transducers to other instruments.

When ordering 9200 and 74712 Seismoprobe Velocity Transducers, expect approximately a six week lead time. Lead times may vary based on component availability and configuration. Contact your local Bently Nevada representative for projected lead times for your specific order.

Technical Specifications

Specifications are measured at approximately +22°C (+72°F) with 25 mm/s (1 in/s) of machine casing vibration at 100 Hz (6000 cpm) with a 10 kΩ load unless otherwise specified.

Parameter Specification
Sensitivity 20 mV/mm/s (500 mV/in/s), ±5% when properly terminated and oriented at the angle of calibration
Calibration Load 10 kΩ Terminal "A" to "B"
Output taken across pins "A" and "B"
Sensitivity Temperature Coefficient 0.2%/°C
Frequency Response 4.5 to 1000 Hz (270 to 60,000 CPM); +0, -3dB typical
10 to 1000 Hz (600 to 60,000 CPM); +0, -3dB typical
15 to 1000 Hz (900 to 60,000 CPM); +0, -3dB typical
Dynamic Operating Range 2.54 mm (0.100 in) peak to peak maximum displacement
Velocity Range 25 mm/s (1 in/s) at +22°C of casing vibration at 100 Hz with a 10 kΩ load
Coil Resistance 1.25 kΩ ±5%
Locked Coil Inductance 125 mH, typical
Amplitude Linearity ±5% from 0.01 to 5.0 in/s (0.254 to 127 mm/s) at 100Hz (6000CPM)
Shock Resistance Withstands 50 g peak maximum acceleration along non-sensitive axis
Transverse Sensitivity ±10% maximum of the sensitive axis sensitivity at 100 Hz and 1.0 in/s (2.54 cm/s)
Polarity of Output Signal Pin A goes positive with respect to Pin B when the transducer case velocity is towards the connector
Lead Wire Length 305 meters (1,000 feet) maximum between Seismoprobe Velocity Transducer and 3300 or Bently Nevada™ 3500 Monitor. Consult manual for frequency roll-off at longer lengths.
Environmental Limits
Parameter Specification
Operating and Storage Temperature 9200: -29°C to +121°C (-20°F to +250°F)
74712: -29°C to +204°C (-20°F to +400°F)
Environment Dust and moisture resistant. Contact your Sales Professional regarding transducer operation in a radiation environment.
Relative Humidity To 95%, noncondensing. 100%, non-submerged, when ordered with integral cable.
Maximum Use Altitude 2000 m (6,561 ft) above sea level.
Ordering Information

Two-wire Transducer Ordering Format: 9200-AA-BB-CC-DD

Option Description
A: Transducer Mounting Angle/Minimum Operating Frequency Option 01: 0 ±2.5, 4.5 Hz (270 cpm)
02: 45 ±2.5, 4.5 Hz (270 cpm)
03: 90 ±2.5, 4.5 Hz (270 cpm)
06: 0 ±100, 10 Hz (600 cpm)
09: 0 ±180, 15 Hz (900 cpm)
B: Connector/Cable Option 01: Top Mount (no cable)
02: Side Mount (no cable)
05: Terminal block top mount (no cable)
10 through 50: Integral hardline cable
Standard cable lengths:
10: 10 feet (3.0 meter)
15: 15 feet (4.6 meter)
22: 22 feet (6.7 meter)
32: 32 feet (9.8 meter)
50: 50 feet (15.2 meter)
Other cable lengths between 7 feet and 50 feet may be available through custom products.
C: Mounting Base Option 01: Circular; 1/4-20 UNC stud
02: Circular; 1/4-28 UNF stud
03: Rectangular flange
04: Circular; with three 8-32 threaded studs on a 44 mm (1.75 in) diameter bolt circle
05: No base; 1/2-20 UNF-3A stud
06: Isolated circular 1/4-20 UNC stud
07: Isolated circular 1/4-28 UNF stud
08: Isolated rectangular flange
09: Isolated circular 5/8-18 UNF stud
10: Circular; M10X1 stud
11: Isolated circular M10X1
12: Isolated circular 1/2-20 UNF-2A
D: Agency Approval Option 00: No Approvals
01: CSA
04: ATEX/IECEx

Συνιστώμενα προϊόντα