2026-09-10
In Germany's chemical and lubrication system industry, overfill protection for viscous liquid tanks remains a selection challenge. Conventional float switches may respond slowly in sticky media, while conductive and capacitive sensors can be affected by conductivity, buildup, turbulence, or air bubbles. The customer needed a compact point level switch with 316L stainless steel wetted parts and suitability for viscous liquids.
Country/Market: Germany
Customer Type: Chemical tank and lubrication system integrator
Application: Viscous liquid tank, overfill protection (MAX safety mode)
Media Conditions: Dynamic viscosity 1 to 10,000 mPa·s, density > 0.7 g/cm³
Process Temperature: Up to 100°C
Process Pressure: -1 to +40 bar
Product: Liquiphant FTL31
Key Configuration: 3-wire DC-PNP, M12 plug, 316L stainless steel housing, compact version
Quantity: 20 units
Delivery: Standard lead time, subject to order confirmation
Mounting: Horizontal installation on tank sidewall, wall distance ≥ 10 mm
Safety Mode: MAX safety mode for overfill protection
Function Test: External function test with test magnet, LED indication
During commissioning, the customer used the test magnet for external function testing and confirmed the switching state via LED indication. Because FTL31 uses the tuning fork measuring principle with no moving parts, it did not show the mechanical sticking issues common to float switches in viscous media. The customer acknowledged the compact design and M12 plug connection.
Measuring Principle: Vibronic tuning fork
Suitable Media: Liquids
Dynamic Viscosity: 1 to 10,000 mPa·s
Density: > 0.7 g/cm³
Solids Content: θ < 5 mm
Process Temperature: -40 to +100°C (standard version)
Process Pressure: -1 to +40 bar
Wetted Material: 316L stainless steel
Output: 3-wire DC-PNP, 10 to 30 V DC, switching capacity 200 mA
Protection: M12 metal housing cover IP66/68/69
Switch Point Repeatability: ±1 mm (DIN 61298-2)
Hysteresis: Max. 3 mm
Vibration Resistance: 50 m/s² RMS
Shock Resistance: 30 g
Not Suitable: Hazardous areas; FTL33 recommended for hygiene areas
The customer noted that FTL31 offers clear parameter boundaries, making it easier to confirm whether viscosity, density, temperature, and pressure match the application during selection. After installation, the device status can be observed directly via LED, reducing communication effort during commissioning and maintenance.
For overfill protection of viscous liquids in German chemical and lubrication systems, FTL31 provides a verifiable selection path based on the tuning fork principle. Its viscosity range, density range, 316L wetted materials, and MAX safety mode form the basis for stable operation in this application. If the application involves hazardous areas or hygiene areas, explosion-proof models or FTL33 should be considered respectively.